Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Modèle: HLG-150H
marque: Meanwell
Détails d'emballage: Boîte
productivité: 20000pcs per month
transport: Ocean,Land,Air
Lieu d'origine: Guangdong, Chine
Soutenir: 5000pcs per month
Hafen: Shenzhen,Guangzhou,Hongkong
Type de paiement: T/T,Paypal,Money Gram,Western Union
Incoterm: FOB,CIF
HLG-150H Meanwell Waterproof LED Alimentation
Description des produits
Alimentation d'énergie de commutation à sortie unique imperméable 150W , le modèle suivant largement utilisé avec des lampes de l `Iseeled conduit, HLG-150 H - 12, HLG-150 H -1 5, HLG-150 H -24, etc un autre modèle pour lampes spéciales avec différentes tensions d'entrée.
HLG-150 H -12 Blank: IP67 évalué. Câble pour la connexion d'E / S.
HLG-150 H -12A: IP65 évalué. La tension de sortie et le niveau de courant constant peuvent être ajustés par l'intermédiaire du potentiomètre interne.
HLG-150 H -12B: IP67 évalué. Niveau de courant constant réglable par le câble de sortie avec le signal ou la résistance de 1 ~ 10Vdc ou de PWM.
HLG-150 H -12D (option): IP67 évalué. Fonction de gradation de temporisateur, contactez MEAN WELL pour plus de détails.
Model |
HLG-150H-12 |
HLG-150H-15 |
HLG-150H-24 |
|
Output |
DC VOLTAGE |
12V |
15V |
24V |
CURRENT ADJ. RANGE |
Can be adjusted by internal potentiometer A type only |
|||
7.5-12.5A |
6-10A |
3.8-6.3A |
||
RATED POWER |
150W |
150W |
151.2W |
|
VOLTAGE ADJ. RANGE |
10.8-13.5V |
13.5-17V |
22-27V |
|
Input |
Voltage Range |
90-264VAC 127-370V DC |
||
Frequency Range |
47-63Hz |
|||
POWER FACTOR |
PF>0.98/115VAC, PF>0.95/230VAC, at full load (Please refer to "Power Factor Characteristic" curve) |
|||
Efficiency(Typ.)(230Vac) |
92% |
92.5% |
93.5% |
|
AC CURRENT (Typ.) |
1.7A / 115VAC 0.75A / 230VAC |
|||
INRUSH CURRENT(Typ.) |
COLD START 75A/230VAC |
|||
LEAKAGE CURRENT |
<0.75mA / 240VAC |
|||
PROTECTION |
OVER LOAD |
95~ 108% |
||
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
||||
SHORT CIRCUIT |
Constant current limiting, recovers automatically after fault condition is removed |
|||
OVER VOLTAGE |
14-17V |
18-21V |
28-34V |
|
Protection type :Shut down O/P voltage, re-power on to recover |
||||
OVER TEMPERATURE |
100 ℃ up or less10 ℃ (RTH2) |
|||
Protection type : Shut down and latch off o/p voltage, recovers automatically after temperature goes down |
||||
Environment |
WORKING TEMP. |
-40 ~ +70 ℃(Refer to output load derating curve) |
||
WORKING HUMIDITY |
20 ~ 95% RH non-condensing |
|||
SAFETY |
SAFETY STANDARDS |
UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1, J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1 |
||
WITHSTAND VOLTAGE |
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC |
|||
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25 / 70% RH |
|||
EMC EMISSION |
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3 |
|||
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A |
|||
Others |
MTBF |
192.2K hrs min. MIL-HDBK-217F (25℃ ) |
||
DIMENSION |
228*68*38.8mm (L*W*H) |
|||
PACKING |
1.15Kg; 12pcs/14.8Kg/0.8CUFT |
|||
Note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the static characteristics for more details. 5. Type A only. 6. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 9. Refer to warranty statement. |
1. Tous les paramètres NON spécialement mentionnés sont mesurés à l'entrée 230VAC, la charge nominale et 25 de la température ambiante. Remarque
2. L'ondulation et le bruit sont mesurés à 20 MHz de bande passante à l'aide d'un câble à paire torsadée de 12 "terminé par un condensateur parallèle de 0,uf et 47uf.
3. Tolérance: inclut la tolérance de configuration, la régulation de ligne et la régulation de charge.
4. Derating peut être nécessaire sous des tensions d'entrée faibles. Veuillez vérifier les caractéristiques statiques pour plus de détails.
5. Tapez A seulement.
6. La sécurité et la conception CEM se réfèrent aux normes EN60598-1, CNS15233, GB7000.1, FCC part18.
7. La longueur du temps d'installation est mesurée au premier démarrage à froid. Allumer / éteindre l'alimentation peut entraîner une augmentation du temps d'installation.
8. L'alimentation est considérée comme un composant qui sera utilisé en combinaison avec l'équipement final. Étant donné que les performances CEM seront affectées par En cas d'installation complète, les fabricants d'équipements finaux doivent à nouveau requalifier la directive CEM sur l'installation complète.
9. Reportez-vous à la déclaration de garantie.Groupes de Produits : Accessoires LED > Alimentation étanche Meanwell
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.